Request pricing
DPL · SHR · E-LIGHT PLATFORM

LUMERA DPL

Two filtered spectra. Five treatments. One console.

Two handpieces, SHR and E-LIGHT modes, and four-stage cooling keep every session fast and comfortable.

2 filtered spectra2 spectra 1–10 Hz In-Motion1–10 Hz 4000 W output4000 W
Narrow-spectrum filtering

Broad light, filtered twice.

A conventional flashlamp emits a wide band and lets the skin sort it out. DPL cuts that output down to two narrow windows, so wavelengths outside the target band never reach the patient.

Unfiltered flashlamp output
530–750 nm · skin
640–750 nm · hair
530 640 750 nm
530–750 nm

Narrow-spectrum light in this band produces photothermal and photochemical effects in the deep dermis, where collagen and elastic fibres are rearranged.

640–750 nm

Compressing the spectrum here balances melanin absorption against penetration depth, so the energy that arrives is the energy that reaches the follicle.

ONE PLATFORM, FIVE SERVICES

Five services from one treatment room.

Hair removal and skin work usually mean two machines and two rooms. LUMERA DPL carries two filtered handpieces and two working modes on one console, so a single room can run the full list.

  • Two handpieces, each with its own filtered spectrum
  • Two working modes — In-Motion and Stamp
  • Skin contact held between 0 and 10 °C
Zilica LUMERA DPL console at a three-quarter angle, showing the tilting touchscreen, emergency stop and key switch, side ventilation, and a docked handpiece
Clinic performance

What the platform is built to hold steady.

Every pulse the same shape

OPT and AFT replace the sharp triangular output of older flashlamp systems with a flat, repeated pulse — so penetration depth stays consistent shot to shot.

Four-stage cooling

Semiconductor, air, water and cooling gel work together to hold the skin contact surface between 0 and 10 °C.

In-Motion up to 10 Hz

Repetition runs from 1 to 10 Hz, so a large area can be covered in a continuous gliding pass instead of shot by shot.

Room for the energy you need

A 4000 W platform across a 10 × 50 mm spot, adjustable from 1–15 J/cm² in SHR and 1–50 J/cm² in E-LIGHT.

The two LUMERA DPL handpieces side by side — one filter window glowing red, the other amber, showing the machine's two filtered spectra
TWO HANDPIECES, ONE CONSOLE

Change the spectrum, not the machine.

Each handpiece carries its own optical filter — 640–750 nm on one, 530–750 nm on the other. Changing what you treat means changing the applicator, not buying a second platform.

Real sapphire window
1,000,000 shots
10 × 50 mm spot
Dual filtered wavelengths
Treatment range

Five treatments the platform is built for.

A smooth, hair-free lower leg and calf against a pale lilac studio backdrop
Hair removal
Fingertips gently resting on a cheek and jawline with luminous, dewy, even-toned skin
Skin rejuvenation
Close crop of the back of a hand showing natural sun spots and soft uneven pigmentation
Pigment therapy
Macro close-up of the back of a calf showing a fine network of visible spider veins
Vascular therapy
Side profile close-up of a cheek and jawline showing a natural acne breakout
Acne treatment
Specifications

Professional technology,
clearly defined.

Optics and energy
Wavelengths 530–750 nm · 640–750 nm
Output power 4000 W
DPL energy SHR 1–15 J/cm² · E-LIGHT 1–50 J/cm²
RF energy 1–50 J/cm²
Pulses per shot SHR single pulse · E-LIGHT 1–6 pulses
RF delay SHR 1–100 ms · E-LIGHT 1–500 ms
Repetition rate 1–10 Hz
Spot size 10 × 50 mm
Handpieces 2, each with 1,000,000 shots
Working modes In-Motion and Stamp
Console, cooling and logistics
Controller 15″ TFT true-colour LCD
Interface languages English, Spanish, Turkish, Russian and others
Cooling Semiconductor, air, water and cooling gel
Skin contact temperature 0–10 °C
Voltage 110 V / 220 V
Machine dimensions 47 × 47 × 109 cm
Net weight 57 kg
Shipping dimensions 67 × 63 × 123 cm
Gross weight 83 kg
Shipping case Aluminium alloy

Specifications are the manufacturer's and may change without notice. Ask us for the current data sheet before you order.

Zilica partnership

Supported beyond delivery.

01

Machine selection

Guidance tailored to your clinic, goals, and service offering.

02

Training and onboarding

Practical setup and operator training for a confident launch.

03

Ongoing technical support

Technical help from a team that knows the machine you bought.

Bring LUMERA to your clinic

One platform. Five services. One conversation.

Pricing, lead times, and an honest answer on fit.

DPL · SHR · E-LIGHT PLATFORM

LUMERA DPL

Two filtered spectra. Five treatments. One console.

Two handpieces, SHR and E-LIGHT modes, and four-stage cooling keep every session fast and comfortable.

2 filtered spectra2 spectra 1–10 Hz In-Motion1–10 Hz 4000 W output4000 W
Narrow-spectrum filtering

Broad light, filtered twice.

A conventional flashlamp emits a wide band and lets the skin sort it out. DPL cuts that output down to two narrow windows, so wavelengths outside the target band never reach the patient.

Unfiltered flashlamp output
530–750 nm · skin
640–750 nm · hair
530 640 750 nm
530–750 nm

Narrow-spectrum light in this band produces photothermal and photochemical effects in the deep dermis, where collagen and elastic fibres are rearranged.

640–750 nm

Compressing the spectrum here balances melanin absorption against penetration depth, so the energy that arrives is the energy that reaches the follicle.

ONE PLATFORM, FIVE SERVICES

Five services from one treatment room.

Hair removal and skin work usually mean two machines and two rooms. LUMERA DPL carries two filtered handpieces and two working modes on one console, so a single room can run the full list.

  • Two handpieces, each with its own filtered spectrum
  • Two working modes — In-Motion and Stamp
  • Skin contact held between 0 and 10 °C
Zilica LUMERA DPL console at a three-quarter angle, showing the tilting touchscreen, emergency stop and key switch, side ventilation, and a docked handpiece
Clinic performance

What the platform is built to hold steady.

Every pulse the same shape

OPT and AFT replace the sharp triangular output of older flashlamp systems with a flat, repeated pulse — so penetration depth stays consistent shot to shot.

Four-stage cooling

Semiconductor, air, water and cooling gel work together to hold the skin contact surface between 0 and 10 °C.

In-Motion up to 10 Hz

Repetition runs from 1 to 10 Hz, so a large area can be covered in a continuous gliding pass instead of shot by shot.

Room for the energy you need

A 4000 W platform across a 10 × 50 mm spot, adjustable from 1–15 J/cm² in SHR and 1–50 J/cm² in E-LIGHT.

The two LUMERA DPL handpieces side by side — one filter window glowing red, the other amber, showing the machine's two filtered spectra
TWO HANDPIECES, ONE CONSOLE

Change the spectrum, not the machine.

Each handpiece carries its own optical filter — 640–750 nm on one, 530–750 nm on the other. Changing what you treat means changing the applicator, not buying a second platform.

Real sapphire window
1,000,000 shots
10 × 50 mm spot
Dual filtered wavelengths
Treatment range

Five treatments the platform is built for.

A smooth, hair-free lower leg and calf against a pale lilac studio backdrop
Hair removal
Fingertips gently resting on a cheek and jawline with luminous, dewy, even-toned skin
Skin rejuvenation
Close crop of the back of a hand showing natural sun spots and soft uneven pigmentation
Pigment therapy
Macro close-up of the back of a calf showing a fine network of visible spider veins
Vascular therapy
Side profile close-up of a cheek and jawline showing a natural acne breakout
Acne treatment
Specifications

Professional technology,
clearly defined.

Optics and energy
Wavelengths 530–750 nm · 640–750 nm
Output power 4000 W
DPL energy SHR 1–15 J/cm² · E-LIGHT 1–50 J/cm²
RF energy 1–50 J/cm²
Pulses per shot SHR single pulse · E-LIGHT 1–6 pulses
RF delay SHR 1–100 ms · E-LIGHT 1–500 ms
Repetition rate 1–10 Hz
Spot size 10 × 50 mm
Handpieces 2, each with 1,000,000 shots
Working modes In-Motion and Stamp
Console, cooling and logistics
Controller 15″ TFT true-colour LCD
Interface languages English, Spanish, Turkish, Russian and others
Cooling Semiconductor, air, water and cooling gel
Skin contact temperature 0–10 °C
Voltage 110 V / 220 V
Machine dimensions 47 × 47 × 109 cm
Net weight 57 kg
Shipping dimensions 67 × 63 × 123 cm
Gross weight 83 kg
Shipping case Aluminium alloy

Specifications are the manufacturer's and may change without notice. Ask us for the current data sheet before you order.

Zilica partnership

Supported beyond delivery.

01

Machine selection

Guidance tailored to your clinic, goals, and service offering.

02

Training and onboarding

Practical setup and operator training for a confident launch.

03

Ongoing technical support

Technical help from a team that knows the machine you bought.

Bring LUMERA to your clinic

One platform. Five services. One conversation.

Pricing, lead times, and an honest answer on fit.